KITSET HOUSE STANDARD SPECIFICATION

SUB FLOOR

  • Standard Piles - H5 Treated 125x125 Square - 900mm
     
  • Anchor Piles - H5 Treated 125x125 Square - 1500mm 

     Optional Extra  Purpose
    Under Pile Disk - Conqru Lightfoot Pile System Disk Secured to underside of pile by helix fixing - negates the need for concrete around piles

     
  • Fixings   - 6KN Galvanised Fixing System - Bearer to Standard Pile
                - 12KN Galvanised Fixing System - Bearer to Anchor Pile

     Optional Extra  Purpose
    Upgrade from Galvanised fixings to Stainless Steel Recommended in coastal areas to prevent against corrosion

     
  • Bearers 150x50 Radiata No1 H3 Treated, Rough Sawn 
     
  • Floor Joists and Blocking - Engineered Laminated Veneer Lumber, H3 Treated

     6.0m Wide and less models  150x45
     7.2m Wide models  170x45

      
  • Boundary Joists and Blocking - Engineered Laminated Veneer Lumber, H3 Treated 
     
  • Base Boards - 100x25 H3 Treated, Rough Sawn
     
  • Hardware  - Access Door Hindges 200mm Galvanised
                  - Access Door 150mm 
                  - Pad Bolt 150mm Galvanised

FLOORING

  • Sub Floor Insulation - 422 Rolls or 1250mm x 60m of Double Side Perforated Sisalation
     
  • 17mm Plyfloor treated with screw fixings

Sub Floor & Flooring deleted from supply for slab foundations

Fixing down connections included (Panels to slab included for concrete slab construction)


VERAHDAH & DECK

  • Verandah and Deck as per Plan Dimensions
     
  • Beam supported on 90x90 Laminiated Posts all Treated H3
     
  • Galvanised 'Beam to Post' Brackets and Bolts

     Optional Extra  Purpose
    Upgrade from Galvanised fixings to Stainless Steel fixings Recommended in coastal areas to prevent against corrosion
     
  • 12.0mm Plygroove to underside of Verandah Treated H3
     
  • 200 x 50mm Bearers Treated H3
     
  • 150 x 50mm Radiata Pine Joists Treated H3
     
  • 100 x 25mm Radiata Pine Grip Tread Decking

PERIMETER PANELS©

  • EZYasPLY™ Panel System (Unique Trademark Panel System - Cyclonic & Earthquake Resistant)
     
  • Timber Frame Construction90x45 Kiln Dried Treated H3
     
  • Pre-drilled for Services
     
  • 90 x 90mm Glulam (Glue Laminated) Corner Posts
     
  • Internal Side of Panel lined with 9.0mm Eliteline Plywood Panelling
  •  Panels Bolted together with M10 Galvanised Engineers Bolts
     
  • Panels Fixed down with Sheet Brace Cyclone Ties
     
  • 90 x 45mm Machine Profiled Top Plate Treated H3

LINTELS

  •  200 x 90mm Engineered Lintels Treated H3

EXTERIOR LINING

  •  12.0mm Shadow Cladd Bandsawn Treated H3 and Preprimed over Building Paper

(also supplied without prepriming for stained finish)

INSULATION

  • R1.8 to Walls
     
  • R2.6 to Ceiling

     Optional Extra Purpose 
    Upgrade (or delete) insulation R rating Additional insulation can be added for particularly cold regions

INTERIOR WALLS©

  • EZYasPLY™ Panel System (Unique Trademark Panel System - Cyclonic & Earthquake Resistant)
     
  • Timber Frame Construction 90x45mm H3 Klin Dried
     
  • Panels lined with 9.0mm Eliteline Plywood Panelling
     
  • Pre Drilled for Services
     
  • Panels bolted together with M10 Galvanised Engineers Bolts
     
  • 60 x 18mm Radiata Pine Finger Jointed Skirting
     
  • 30 x 10mm Clashing Strips around Windows

RIDGE BEAM & RAFTERS

  • Engineered Ridge Beam (240x63 or 300x63mm depending on model)
     
  • Engineered Rafters Factory Cut (150x45mm or 170x45mm depending on model)
     
  • Powder Coated Preformed Connection Brackets (Rafters to Ridge Beam)
     
  • Cyclone Ties and Strap Bracing

ROOF LINING

  • 12.0mm Plygroove treated
     
  • 100 x 50mm Purlins secured with Purlin Cleats
     
  • Self Supporting Underlay
     
  • Longrun Colorsteel Iron Standard Finishing

     Optional Extra  Purpose

    1. Upgrade from Standard Finishing to Coastal Grade Finishing

    2. Upgrade Ceiling Lining to Blush Ply

    Recommended in coastal areas to prevent against corrosion

    Pre-painted for easy of finishing

     
  • Barge Flashings
     
  • Colour Profile Cyclone Washers
     
  • Colour Profile Cyclone Screws

SOFFITS

  • Cement Board
     
  • PVC Jointers

EXTERIOR JOINERY

  • Powder Coated Aluminium Joinery
     
  • Standard Window Opening is Awning/Sash Style (open out)
  • Safety Glass Supplied Standard to Educational Teaching Models

     Optional Extra                                Purpose
    Upgrade to double glazing Additional thermal insulation
    Change Sash Opening to Louvre Opening Client Preference
    Change Sash Opening to Sliding Client Preference
     
     
  • Timber Revels Treated H3
     

INTERIOR DOORS

  • Paint Quality Doors
     
  • Wardrobe Sliding Doors and Tracking Gear

INTERIOR HARDWARE

  • All Door Handles, Door Stops and Cabin Hooks
     
  • Closet Bars and Brackets for Wardrobes
     
  • 400 x 18mm Lakepine Shelf to Wardrobes
     
  • Hot Water Cupboard and Shelf

FASCIA

  •  200 x 40mm Radiata Pine Rough Sawn Fascia Boards Treated H3

KITCHEN

  • Modular Kitchen System (as per plan details) Supplied Flat Packed with all Hardware
     
  • Melteca Cabinets in Choice of Twelve Colours
  • Formica Laminated Bench Top in a Choice of Colours

APPLIANCES

  •  Not included

RAINWATER SYSTEM

  • Marley Classic Rainwater System
     
  • Classic Spouting
     
  • Classic Clips, Brackets, Solvent and Accessories
     
  • 65mm Downpipes

NAIL & FIXINGS

  •  All Nails and Fixings required to construct

PLUMBING FITTINGS

  • Kitchen Sink Mixer (Chrome)
     
  • Shower Enclosures and Doors (with Easy Clean Traps)
     
  • Shower Mixers
     
  • Shower Roses
     
  • Toilet Pans and Cisterns
     
  • Laundry Tub and Taps
     
  • Vanity Units as shown on Plans
     
  • Taps for Vanity Units

OPTION PACKS (Pricing on Request)

1. Solar Water Heating System

Circulatory and Pacific Islands Kits available - details on request (see links page to Sola60).